Journal of Thermal Science and Engineering Applications

Temperature Elevation in the Human Eye Due To Intraocular Projection Prosthesis Device
Gongal D, Thakur S, Panse A, Stark JA, Yu CQ and Foster CD
Corneal opacity is a leading cause of blindness worldwide. Corneal transplantation and keratoprosthesis can restore vision but have limitations due to the shortage of donor corneas and complications due to infection. A proposed alternative treatment using an intraocular projection prosthesis device can treat corneal disease. In this study, we perform a transient thermal analysis of the bionic eye model to determine the power the device can produce without elevating the eye tissue temperature above the 2°C limit imposed by the international standard for implantable devices. A 3D finite element model, including blood perfusion and natural convection fluid flow of the eye, was created. The device was placed 1.95 mm from the iris, which experienced less than 2°C rise in the tissue temperature at a maximum power dissipation of LED at 100 mW and microdisplay at 25 mW.
Thermal Model of an Omnimagnet for Performance Assessment and Temperature Control
Esmailie F, Cavilla MS, Abbott JJ and Ameel TA
An Omnimagnet is an electromagnetic device that enables remote magnetic manipulation of devices such as medical implants and microrobots. It is composed of three orthogonal nested solenoids with a ferromagnetic core at the center. Electrical current within the solenoids leads to undesired temperature increase within the Omnimagnet. If the temperature exceeds the melting point of the wire insulation, device failure may occur. Thus, a study of heat transfer within an Omnimagnet is a necessity, particularly to maximize the performance of the device. A transient heat transfer model that incorporates all three heat transfer modes is proposed and experimentally validated with an average normalized root-mean-square error of less than 4% (data normalized by temperature in degree celsius). The transient model is not computationally expensive and is applicable to Omnimagnets with different structures. The code is applied to calculate the maximum safe operational time at a fixed input current or the maximum safe input current for a fixed time interval. The maximum safe operational time and maximum safe input current depend on size and structure of the Omnimagnet and the lowest critical temperature of all the Omnimagnet materials. A parametric study shows that increasing convective heat transfer during cooling, and during heating with low input currents, is an effective method to increase the maximum operational time of the Omnimagnet. The thermal model is also presented in a state-space equation format that can be used in a real-time Kalman filter current controller to avoid device failure due to excessive heating.
Underground Mine Refuge Alternatives Heat Mitigation
Yan L, Yantek D, Lutz T, Yonkey J and Srednicki J
In case of an emergency in an underground coal mine, miners who fail to escape from the mine can enter a refuge alternative (RA) for protection from adverse conditions, such as high carbon monoxide levels. One of the main concerns with the use of both portable and built-in-place (BIP) RAs, especially for hot or deep mines, is the interior temperature rise due to the occupants' metabolic heat and the heat released by devices such as the carbon dioxide (CO) scrubbing system. The humidity within the RA will also increase through occupants' respiration and perspiration and from the chemical reaction within the CO scrubbing system. Heat and humidity buildup can subject the occupants to hazardous thermal conditions. To protect RA occupants, Mine Safety and Health Administration regulations mandate a maximum apparent temperature of 95 °F within an occupied RA. The National Institute for Occupational Safety and Health (NIOSH) tested both an air-conditioned borehole air supply (BAS) and a cryogenic air supply for RAs in the NIOSH Experimental Mine in Bruceton, PA. The BAS was tested on a 60-person BIP RA, while the cryogenic air supply was tested on a 30-person BIP RA and a portable 23-person tent-type RA. Multiple tests were conducted with both air supplies to assess their ability to cool RAs. The test results show that the BAS and the cryogenic air supply were able to maintain the apparent temperature within the tested RAs under the 95 °F limit. The BAS and the cryogenic air supply are potential RA heat mitigation strategies that mines could use to prevent heat/humidity buildup within RAs.
Effects of Femtosecond Laser Surface Processed Nanoparticle Layers on Pool Boiling Heat Transfer Performance
Kruse C, Lucis M, Shield JE, Anderson T, Zuhlke C, Alexander D, Gogos G and Ndao S
An experimental investigation of the effects of layers of nanoparticles formed during femtosecond laser surface processing (FLSP) on pool boiling heat transfer performance has been conducted. Five different stainless steel 304 samples with slightly different surface features were fabricated through FLSP, and pool boiling heat transfer experiments were carried out to study the heat transfer characteristics of each surface. The experiments showed that the layer(s) of nanoparticles developed during the FLSP processes, which overlay FLSP self-organized microstructures, can either improve or degrade boiling heat transfer coefficients (HTC) depending on the overall thickness of the layer(s). This nanoparticle layer thickness is an indirect result of the type of microstructure created. The HTCs were found to decrease with increasing nanoparticle layer thickness. This trend has been attributed to added thermal resistance. Using a focused ion beam milling process and transmission electron microscopy (TEM), the physical and chemical properties of the nanoparticle layers were characterized and used to explain the observed heat transfer results. Results suggest that there is an optimal nanoparticle layer thickness and material composition such that both the HTCs and critical heat flux (CHF) are enhanced.
Optimal Design of Wavelength Selective Thermal Emitter for Thermophotovoltaic Applications
Ghanekar A, Sun M, Zhang Z and Zheng Y
We theoretically and numerically demonstrate optimal design of wavelength selective thermal emitter using one-dimensional (1D) and two-dimensional (2D) metal-dielectric gratings for thermophotovoltaic (TPV) applications. Proposed design consists of tungsten (W) and silicon dioxide (SiO) gratings which can withstand high temperatures. Radiative properties of 1D grating were calculated using a numerical method, while effective medium approximation was used for 2D gratings. Optimal designs were obtained such that output power is maximum for GaSb photovoltaic (PV) cell at emitter temperature of 1500 K and radiated energy for longer wavelengths is limited to a low value. A constrained optimization was performed using genetic algorithm (GA) to arrive at optimal design.
Temperature Rise Within a Mobile Refuge Alternative-Experimental Investigation and Model Validation
Yan L, Yantek D, Klein M, Bissert P and Matetic R
Mine Safety and Health Administration (MSHA) regulations require underground coal mines to install refuge alternatives (RAs). In the event of a disaster, RAs must be able to provide a breathable air environment for 96 h. The interior environment of an occupied RA, however, may become hot and humid during the 96 h due to miners' metabolic heat and carbon dioxide scrubbing system heat. The internal heat and humidity may result in miners suffering heat stress or even death. To investigate heat and humidity buildup with an occupied RA, the National Institute for Occupational Safety and Health (NIOSH) conducted testing on a training ten-person, tent-type RA in its Safety Research Coal Mine (SRCM) in a test area that was isolated from the mine ventilation system. The test results showed that the average measured air temperature within the RA increased by 11.4°C (20.5 °F) and the relative humidity approached 90% RH. The test results were used to benchmark a thermal simulation model of the tested RA. The validated thermal simulation model predicted the average air temperature inside the RA at the end of 96 h to within 0.6 °C (1.1 °F) of the measured average air temperature.
Impact, Fire, and Fluid Spread Code Coupling for Complex Transportation Accident Environment Simulation
Brown AL, Wagner GJ and Metzinger KE
Transportation accidents frequently involve liquids dispersing in the atmosphere. An example is that of aircraft impacts, which often result in spreading fuel and a subsequent fire. Predicting the resulting environment is of interest for design, safety, and forensic applications. This environment is challenging for many reasons, one among them being the disparate time and length scales that are necessary to resolve for an accurate physical representation of the problem. A recent computational method appropriate for this class of problems has been described for modeling the impact and subsequent liquid spread. Because the environment is difficult to instrument and costly to test, the existing validation data are of limited scope and quality. A comparatively well instrumented test involving a rocket propelled cylindrical tank of water was performed, the results of which are helpful to understand the adequacy of the modeling methods. Existing data include estimates of drop sizes at several locations, final liquid surface deposition mass integrated over surface area regions, and video evidence of liquid cloud spread distances. Comparisons are drawn between the experimental observations and the predicted results of the modeling methods to provide evidence regarding the accuracy of the methods, and to provide guidance on the application and use of these methods.