Aerosol and Air Quality Research

Ambient PM temporal variation and source apportionment in Mbarara, Uganda
Onyango S, North CM, Ellaithy HA, Tumwesigye P, Kang CM, Matthaios V, Mukama M, Nambogo N, Wolfson JM, Ferguson S, Asiimwe S, Atuyambe L, Santorino D, Christiani DC and Koutrakis P
Air pollution is the leading environmental cause of death globally, and most mortality occurs in resource-limited settings such as sub-Saharan Africa. The African continent experiences some of the worst ambient air pollution in the world, yet there are relatively little African data characterizing ambient pollutant levels and source admixtures. In Uganda, ambient PM levels exceed international health standards. However, most studies focus only on urban environments and do not characterize pollutant sources. We measured daily ambient PM concentrations and sources in Mbarara, Uganda from May 2018 through February 2019 using Harvard impactors fitted with size-selective inlets. We compared our estimates to publicly available levels in Kampala, and to World Health Organization (WHO) air quality guidelines. We characterized the leading PM sources in Mbarara using x-ray fluorescence and positive matrix factorization. Daily PM concentrations were 26.7 μg m and 59.4 μg m in Mbarara and Kampala, respectively (p<0.001). PM concentrations exceeded WHO guidelines on 58% of days in Mbarara and 99% of days in Kampala. In Mbarara, PM was higher in the dry as compared to the rainy season (30.8 vs 21.3, p<0.001), while seasonal variation was not observed in Kampala. PM concentrations did not vary on weekdays versus weekends in either city. In Mbarara, the six main ambient PM sources identified included (in order of abundance): traffic-related, biomass and secondary aerosols, industry and metallurgy, heavy oil and fuel combustion, fine soil, and salt aerosol. Our findings confirm that air quality in southwestern Uganda is unsafe and that mitigation efforts are urgently needed. Ongoing work focused on improving air quality in the region may have the greatest impact if focused on traffic and biomass-related sources.
Real-World Effectiveness of Portable Air Cleaners in Reducing Home Particulate Matter Concentrations
Lu FT, Laumbach RJ, Legard A, Myers NT, Black KG, Ohman-Strickland P, Alimokhtari S, de Resende A, Calderón L, Mainelis G and Kipen HM
Portable air cleaners (PACs) equipped with HEPA filters are gaining attention as cost-effective means of decreasing indoor particulate matter (PM) air pollutants and airborne viruses. However, the performance of PACs in naturalistic settings and spaces beyond the room containing the PAC is not well characterized. We conducted a single-blinded randomized cross-over interventional study between November 2020 and May 2021 in the homes of adults who tested positive for COVID-19. The intervention was air filtration with PAC operated with the HEPA filter set installed ("filter" condition) versus removed ("sham" condition, i.e., control). Sampling was performed in 29 homes for two consecutive 24-hour periods in the primary room (containing the PAC) and a secondary room. PAC effectiveness, calculated as reductions in overall mean PM and PM concentrations during the filter condition, were for the primary rooms 78.8% and 63.9% (n = 23), respectively, and for the secondary rooms 57.9% and 60.4% (n = 22), respectively. When a central air handler (CAH) was reported to be in use, filter-associated reductions of PM were statistically significant during the day (06:00-22:00) and night (22:01-05:59) in the primary rooms but only during the day in the secondary rooms. Our study adds to the literature evaluating the real-world effects of PACs on a secondary room and considering the impact of central air systems on PAC performance.
Effect of Future Climate Change on Stratosphere-to-Troposphere-Exchange Driven Ozone in the Northern Hemisphere
Sahu SK, Chen L, Liu S, Xing J and Mathur R
Future estimates of atmospheric pollutant concentrations serve as critical information for policy makers to formulate current policy indicators to achieve future targets. Tropospheric burden of O is modulated not only by anthropogenic and natural precursor emissions, but also by the downward transport of O associated with stratosphere to troposphere exchange (STE). Hence changes in the estimates of STE and its contributions are key to understand the nature and intensity of future ground level O concentrations. The difference in simulated O mixing ratios with and without the O-Potential Vorticity (PV) parameterization scheme is used to represent the model estimated influence of STE on tropospheric O distributions. Though STE contributions remain constant in Northern hemisphere as a whole, regional differences exist with Europe (EUR) registering increased STE contribution in both spring and winter while Eastern China (ECH) reporting increased contribution in spring in 2050 (RCP8.5) as compared to 2015. Importance of climate change can be deduced from the fact that ECH and EUR recorded increased STE contribution to O in RCP8.5 compared to RCP4.5. Comparison of STE and non-STE meteorological process contributions to O due to climate change revealed that contributions of non-STE processes were highest in summer while STE contributions were highest in winter. EUR reported highest STE contribution while ECH reported highest non-STE contribution. None of the 3 regions show consistent low STE contribution due to future climate change (< 50%) in all seasons indicating the significance of STE to ground level O.
Effects of E-Cigarette Liquid Ratios on the Gravimetric Filter Correction Factors and Real-Time Measurements
Close A, Blackerby J, Tunnell H, Pender J, Soule E and Sousan S
Electronic cigarettes (ECIGs) generate high concentrations of particulate matter (PM), impacting the air quality inhaled by humans through secondhand exposure. ECIG liquids are available commercially and some users create their own "do-it-yourself" liquids, and these liquids often vary in the amounts of their chemical ingredients, including propylene glycol (PG) and vegetable glycerin (VG). Previous studies have quantified PM concentrations in ECIG aerosol generated from liquids containing different PG/VG ratios. However, the effects of these ratios on aerosol instrument filter correction factors needed to measure PM concentrations accurately have not been assessed. Thus, ECIG aerosol filter correction factors for multiple aerosol instruments (SMPS + APS, MiniWRAS, pDR, and SidePak) were determined for five different PG/VG ratios 1) 0PG/100VG, 2) 15PG/85VG, 3) 50PG/50VG, 4) 72PG/28VG, and 5) 90PG/10VG and two different PM sizes, PM (1 μm and smaller) and PM (2.5 μm and smaller). ECIG aerosols were generated inside a controlled exposure chamber using a diaphragm pump and a refillable ECIG device for all the ratios. In addition, the aerosol size distribution and mass median diameter were measured for all five ECIG ratios. PM correction factors (5-7.6) for ratios 1, 2, 3, and 4 were similar for the SMPS + APS combined data, and ratios 1, 2, 3 were similar for the MiniWRAS (~2), pDR (~0.5), and SidePak (~0.24). These data suggest different correction factors may need to be developed for aerosol generated from ECIGs with high PG content. The higher correction factor values for the 90PG/10VG ratio may have resulted from greater PG volatility relative to VG and sensor losses. The correction factors (ratios 1-4) for PM were SMPS + APS data (4.96-7.62), MiniWRAS (2.02-3.64), pDR (0.50-1.07), and SidePak (0.22-0.40). These data can help improve ECIG aerosol measurement accuracy for different ECIG mixture ratios.
Understanding Air Quality Changes after Implementation of Mitigation Measures during a Pandemic: A Scoping Review of Literature in the United States
McElroy S and Vaidyanathan A
Traffic-related emissions continue to be a significant source of air pollution in the United States (US) and around the globe. Evidence has shown that previous policies implemented to restrict-traffic flows have affected air pollution levels. Thus, mitigation strategies associated with the COVID-19 pandemic that modified population-level mobility patterns provide a unique opportunity to study air pollution change across the US. For instance, to slow the spread of the pandemic, state and local governments started implementing various mitigation actions, including stay-at-home directives, social distancing measures, school closures, and travel restrictions. This scoping review aimed to summarize the existing evidence about how air quality changed through mitigation practices throughout the pandemic in the US. We found 66 articles that fit our inclusion criteria. Generally, the consolidated results revealed that nitrogen dioxide (NO) and carbon monoxide (CO) decreased across the country. Studies observed mixed directions and magnitudes of change for fine and coarse particulate matter (PM, PM), ozone (O), and sulfur dioxide (SO). Few articles tried to explain this notable heterogeneity in air quality changes by associating contextual factors, such as mobility, traffic flow, and demographic factors. However, all studies agreed that the change in air pollution was nonuniform across the US and even varied within a city.
Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Use in Indoor Environments
Streuber D, Park YM and Sousan S
Low-cost aerosol sensors open routes to exposure assessment and air monitoring in various indoor and outdoor environments. This study evaluated the accuracy of GeoAir2--a recently developed low-cost particulate matter (PM) monitor--using two types of aerosols (salt and dust), and the effect of changes in relative humidity on its measurements in laboratory settings. For the accuracy experiments, 32 units of GeoAir2 were used, and for the humidity experiments, 3 units of GeoAir2 were used, alongside the OPC-N3 low-cost sensor and MiniWRAS reference instrument. The normal distribution of slopes between the salt and dust aerosols was compared for the accuracy experiments. In addition, the performance of GeoAir2 in indoor environments was evaluated compared to the pDR-1500 reference instrument by collocating GeoAir2 and pDR-1500 at three different homes for five days. For salt and dust aerosols smaller than 2.5 μm (PM), both GeoAir2 (r = 0.96-0.99) and OPC-N3 (r = 0.98-0.99) were highly correlated with the MiniWRAS reference instrument. However, GeoAir2 was less influenced by changes in humidity than OPC-N3. While GeoAir2 reported an increase in mass concentrations ranging from 100% to 137% for low and high concentrations, an increase between 181% and 425% was observed for OPC-N3. The normal distribution of the slopes for the salt aerosols was narrower than dust aerosol, which shows closer slope similarities for salt aerosols. This study also found that GeoAir2 was highly correlated with the pDR-1500 reference instrument in indoor environments (r = 0.80-0.99). These results demonstrate potential for GeoAir2 for indoor air monitoring and exposure assessments.
Environmental Surveillance for SARS-CoV-2 in Two Restaurants from a Mid-scale City that Followed U.S. CDC Reopening Guidance
Li H, Shankar SN, Witanachchi CT, Lednicky JA, Loeb JC, Alam MM, Fan ZH, Mohamed K, Boyette JA, Eiguren-Fernandez A and Wu CY
Since mask use and physical distancing are difficult to maintain when people dine indoors, restaurants are perceived as high risk for acquiring COVID-19. The air and environmental surfaces in two restaurants in a mid-scale city located in north central Florida that followed the Centers for Disease Control and Prevention (CDC) reopening guidance were sampled three times from July 2020 to February 2021. Sixteen air samples were collected for 2 hours using air samplers, and 20 surface samples by using moistened swabs. The samples were analyzed by real-time reverse transcriptase-polymerase chain reaction (RT-PCR) for the presence of SARS-CoV-2 genomic RNA. A total of ~550 patrons dined in the restaurants during our samplings. SARS-CoV-2 genomic RNA was not detected in any of the air samples. One of the 20 surface samples (5%) was positive. That sample had been collected from a plastic tablecloth immediately after guests left the restaurant. Virus was not isolated in cell cultures inoculated with aliquots of the RT-PCR-positive sample. The likelihood that patrons and staff acquire SARS-CoV-2 infections may be low in restaurants in a mid-scale city that adopt CDC restaurant reopening guidelines, such as operation at 50% capacity so that tables can be spaced at least 6 feet apart, establishment of adequate mechanical ventilation, use of a face covering except while eating or drinking, and implementation of disinfection measures.
Investigation of Mask Efficiency for Loose-Fitting Masks against Ultrafine Particles and Effect on Airway Deposition Efficiency
Su WC, Lee J, Xi J and Zhang K
Ultrafine particle (i.e., smaller than 100 nm) in the ambient air is a significant public health issue. The inhalation and deposition of ultrafine particles in the human airways can lead to various adverse health effects. Loose-fitting types of masks are commonly used by the general public in some developing countries for protecting against ultrafine particles in the ambient environment. This research conducted a series of laboratory chamber experiments using two sets of particle sizers and two mannequin heads to study the mask efficiency of selected loose-fitting masks. Results acquired demonstrated that the cloth mask showed a low mask efficiency against ultrafine particles with the mask efficiency generally less than 0.4. The KN95 presented a better mask efficiency among all tested masks with the mask efficiency overall larger than 0.5. In addition, the effect of mask-wearing on the change of ultrafine particle airway deposition efficiency was also investigated in this study. The ultrafine particle deposition efficiency in the airway section studied was found to decrease due to mask-wearing, and the decreases of the deposition efficiencies were similar among all loose-fitting masks tested.
Environmental Surveillance and Transmission Risk Assessments for SARS-CoV-2 in a Fitness Center
Li H, Shankar SN, Witanachchi CT, Lednicky JA, Loeb JC, Alam MM, Fan ZH, Mohamed K, Eiguren-Fernandez A and Wu CY
Fitness centers are considered high risk for SARS-CoV-2 transmission due to their high human occupancy and the type of activity taking place in them, especially when individuals pre-symptomatic or asymptomatic for COVID-19 exercise in the facilities. In this study, air (N=21) and surface (N=8) samples were collected at a fitness center through five sampling events from August to November 2020 after the reopening restrictions were lifted in Florida. The total attendance was ~2500 patrons during our air and environmental sampling work. Air samples were collected using stationary and personal bioaerosol samplers. Moistened flocked nylon swabs were used to collect samples from high-touch surfaces. We did not detect SARS-CoV-2 by rRT-PCR analyses in any air or surface sample. A simplified infection risk model based on the Wells-Riley equation predicts that the probability of infection in this fitness center was 1.77% following its ventilation system upgrades based on CDC guidelines, and that risk was further reduced to 0.89% when patrons used face masks. Our model also predicts that a combination of high ventilation, minimal air recirculation, air filtration, and UV sterilization of recirculated air reduced the infection risk up to 94% compared to poorly ventilated facilities. Amongst these measures, high ventilation with outdoor air is most critical in reducing the airborne transmission of SARS-CoV-2. For buildings that cannot avoid air recirculation due to energy costs, the use of high filtration and/or air disinfection devices are alternatives to reducing the probability of acquiring SARS-CoV-2 through inhalation exposure. In contrast to the perceived ranking of high risk, the infection risk in fitness centers that follow CDC reopening guidance, including implementation of engineering and administrative controls, and use of personal protective equipment, can be low, and these facilities can offer a relatively safe venue for patrons to exercise.
A High-throughput, Robotic System for Analysis of Aerosol Sampling Filters
L'Orange C, Neymark G, Carter E and Volckens J
The determination of accumulated mass on filter-based aerosol samples is the basis for many forms of scientific research and regulatory monitoring of air quality. However, gravimetric analysis of air sampling filters is tedious, time-intensive, and prone to human error. This work describes the development of an utomated A Anayss aciliy (AIRLIFT) for high-throughput gravimetric mass and optical black carbon measurements of filter-based aerosol samples. The AIRLIFT consists of a sealed environmental enclosure, a 6-axis articulating robotic arm, a programmable control system, a filter weighing apparatus, and an optical system for the determination of aerosol black carbon via light attenuation. The system actively monitors microbalance stability and chamber relative humidity. Digital imaging and QR code scanning support sample tracking and data logging. Performance metrics for temperature and humidity control and weight stability were found to meet or exceed minimum requirements set forth by the US Environmental Protection Agency. The AIRLIFT is capable of analyzing approximately 260 filters per day while reducing the required personnel time by a factor of ~4.
The Composition of Emissions from Sanding Corian with Different Sandpapers
Kang S, Liang H, Qian Y and Qi C
Laboratory tests were conducted to characterize the composition of emissions from sanding Corian, a solid-surface composite material mainly composed of alumina trihydrate (ATH) and acrylic polymer. Three sandpaper materials (ceramic, silicon carbide, and aluminum oxide) were tested to distinguish the contribution of aluminum-containing dust in the emission from Corian and sandpaper itself. The result can help identify the main cause of the pulmonary fibrosis from exposure to aluminum-containing dust while sanding Corian. Airborne dust samples were measured using direct-reading instruments and collected using a Micro-Orifice Uniform Deposit Impactor (MOUDI) for estimating the normalized dust generation rate. The size-classified dust samples from MOUDI were analyzed for elemental aluminum content. Additionally, air samples were analyzed for characterizing methyl methacrylate (MMA). The results from the direct-reading instruments reveal that the size distribution of particulate from sanding Corian differs from that of sawing Corian, showing that the size distribution of dust is affected by the fabrication process. The normalized respirable dust generation rate indicates that more respirable dust was generated during sanding Corian board. However, the use of aluminum oxide sandpaper does not result in a higher aluminum content in the respirable dust from sanding Corian, suggesting that the aluminum content of the respirable dust is primarily originated from Corian itself. The generation rates of MMA from sanding did not vary much among all types of sandpapers, and they were much lower than that of sawing, likely due to the higher temperature in the sawing process.
Collection of SARS-CoV-2 Virus from the Air of a Clinic Within a University Student Health Care Center and Analyses of the Viral Genomic Sequence
Lednicky JA, Shankar SN, Elbadry MA, Gibson JC, Alam MM, Stephenson CJ, Eiguren-Fernandez A, Morris JG, Mavian CN, Salemi M, Clugston JR and Wu CY
The progression of COVID-19 worldwide can be tracked by identifying mutations within the genomic sequence of SARS-CoV-2 that occur as a function of time. Such efforts currently rely on sequencing the genome of SARS-CoV-2 in patient specimens (direct sequencing) or of virus isolated from patient specimens in cell cultures. A pilot SARS-CoV-2 air sampling study conducted at a clinic within a university student health care center detected the virus vRNA, with an estimated concentration of 0.87 virus genomes L air. To determine whether the virus detected was viable ('live'), attempts were made to isolate the virus in cell cultures. Virus-induced cytopathic effects (CPE) were observed within two days post-inoculation of Vero E6 cells with collection media from air samples; however, rtRT-PCR tests for SARS-CoV-2 vRNA from cell culture were negative. Instead, three other fast-growing human respiratory viruses were isolated and subsequently identified, illustrating the challenge in isolating SARS-CoV-2 when multiple viruses are present in a test sample. The complete SAR-CoV-2 genomic sequence was nevertheless determined by Sanger sequencing and most closely resembles SARS-CoV-2 genomes previously described in Georgia, USA. Results of this study illustrate the feasibility of tracking progression of the COVID-19 pandemic using environmental aerosol samples instead of human specimens. Collection of a positive sample from a distance more than 2 m away from the nearest patient traffic implies the virus was in an aerosol.
Performance of Four Consumer-grade Air Pollution Measurement Devices in Different Residences
Manibusan S and Mainelis G
There has been a proliferation of inexpensive consumer-grade devices for monitoring air pollutants, including PM and certain gasses. This study compared the performance of four consumer-grade devices-the Air Quality Egg 2 (AQE2), BlueAir Aware, Foobot, and Speck-that utilize optical sensors to measure the PM concentration. The devices were collocated and operated for 7 days in each of three residences, and the PM mass concentrations were compared with those measured by established optical sensing devices, viz., the personal DataRAM and DustTrak DRX, as well as the filter-based Personal Modular Impactor (PMI). Overall, the Foobot and BlueAir displayed the strongest correlations with the direct-reading reference instruments for both the hourly and daily PM mass concentrations. Comparing the 1-hour averages obtained with the DustTrak DRX for all of the residences with those obtained with the Foobot, BlueAir, AQE2, and Speck, the Pearson's correlation coefficients (R's) were 0.80, 0.88, -0.028, and 0.60, respectively. Overall, the strength of the correlation depended on the specific residence, likely due to the differences in aerosol composition. The correlations with the PMI measurements were moderate, with R values of 0.44 and 0.56 for the BlueAir and Foobot, respectively. The correlation coefficients for the daily values obtained with the AQE2 and Speck were -0.59 and 0.70 compared to the PMI. According to a paired -test, the average 24-h PM concentration data obtained using the consumer-grade monitors were statistically different (p > 0.05) from the mass values measured by the gravimetric filters. Overall, this study demonstrates the ability of consumer grade air pollution monitors to report PM trends accurately; however, for accurate mass concentration measurements, these monitors must be calibrated for a particular location and application. Further testing is needed to determine their suitability for long-term indoor field studies.
Regional characteristics of NO column densities from Pandora observations during the MAPS-Seoul campaign
Chong H, Lee H, Koo JH, Kim J, Jeong U, Kim W, Kim SW, Herman JR, Abuhassan NK, Ahn J, Park JH, Kim SK, Moon KJ, Choi WJ and Park SS
Vertical column density (VCD) of nitrogen dioxide (NO2) was measured using Pandora spectrometers at six sites on the Korean Peninsula during the Megacity Air Pollution Studies-Seoul (MAPS-Seoul) campaign from May to June 2015. To estimate the tropospheric NO VCD, the stratospheric NO VCD from the Ozone Monitoring Instrument (OMI) was subtracted from the total NO VCD from Pandora. European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis wind data was used to analyze variations in tropospheric NO VCD caused by wind patterns at each site. The Yonsei/SEO site was found to have the largest tropospheric NO VCD (1.49 DU on average) from a statistical analysis of hourly tropospheric NO VCD measurements. At rural sites, remarkably low NO VCDs were observed. However, a wind field analysis showed that trans-boundary transport and emissions from domestic sources lead to an increase in tropospheric NO VCD at NIER/BYI and KMA/AMY, respectively. At urban sites, high NO VCD values were observed under conditions of low wind speed, which were influenced by local urban emissions. Tropospheric NO VCD at HUFS/Yongin increases under conditions of significant transport from urban area of Seoul according to a correlation analysis that considers the transport time lag. Significant diurnal variations were found at urban sites during the MAPS-Seoul campaign, but not at rural sites, indicating that it is associated with diurnal patterns of NO emissions from dense traffic.
Seasonal Variation in Culturable Bioaerosols in a Wastewater Treatment Plant
Dehghani M, Sorooshian A, Ghorbani M, Fazlzadeh M, Miri M, Badiee P, Parvizi A, Ansari M, Baghani AN and Delikhoon M
Bioaerosols produced from Wastewater Treatment Plants (WWTPs) can pose health risks to plant workers and nearby inhabitants. There is a gap in air quality data for WWTPs in developing countries. The present study aimed to measure airborne bacterial and fungal concentrations in a WWTP in southwestern Iran between September 2015 and May 2016. Active sampling was conducted around operational units, and a total of 600 bacterial and fungal samples were collected. Spatial and seasonal comparisons were made. The highest average concentrations of culturable bacterial aerosol at seasonally dependent locations were, in decreasing order, 2581 ± 401 and 1952 ± 390 CFU m for the selector and aeration tanks, respectively, in autumn; 1363 ± 299 CFU m for the aeration tank in winter; and 1738 ± 350 CFU m for the screw pump in spring. Furthermore, the predominant genera of airborne fungi isolated from the air of the WWTP in all three seasons were spp., spp., spp., spp., and spp. The results of this work emphasize the necessity of controlling WWTP workers' exposure to bioaerosols when bacteria and fungi become aerosolized during aeration.
On the Morphology and Composition of Particulate Matter in an Urban Environment
Zeb B, Alam K, Sorooshian A, Blaschke T, Ahmad I and Shahid I
Particulate matter (PM) plays a vital role in altering air quality, human health, and climate change. There are sparse data relevant to PM characteristics in urban environments of the Middle East, including Peshawar city in Pakistan. This work reports on the morphology and composition of PM in two size fractions (PM and PM) during November 2016 in Peshawar. The 24 hous mass concentration of PM varied from 72 μg m to 500 μg m with an average value of 286 μg m. The 24 hours PM concentration varied from 300 μg m to 1440 μg m with an average of 638 μg m. The morphology, size, and elemental composition of PM were measured using Fourier Transform Infra Red (FT-IR) Spectroscopy and Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray (EDX) Spectroscopy. The size of the analyzed particles by EDX ranged from 916 nm to 22 μm. Particles were classified into the following groups based on their elemental composition and morphology: silica (12%), aluminosilicates (23%), calcium rich (3%), chloride (2%), Fe/Ti oxides (3%), carbonaceous (49%), sulfate (5%), biogenic (3%). The major identified sources of PM are vehicular emissions, biomass burning, soil and re-suspended road dust, biological emissions, and construction activities in and around the vicinity of the sampling site.
Evaluation and Field Calibration of a Low-Cost Ozone Monitor at a Regulatory Urban Monitoring Station
Masiol M, Squizzato S, Chalupa D, Rich DQ and Hopke PK
The performance of a low cost ozone monitor (Aeroqual Series 500 portable gas monitors using a metal oxide sensor for ozone; model OZL) was assessed under field conditions. Ten ozone monitors were calibrated under clean-air laboratory conditions and controlled ozone concentrations of 5 to 100 ppb. Good linearity and response were obtained relative to a research-grade ozone monitor. One monitor was co-located at a regulatory air quality monitoring station that uses a U.S. federal equivalent method (FEM) ozone analyzer. Raw data from the Aeroqual monitor collected over 4 months (June-October) at a 10-minute time-resolution, showed good agreement (r=0.83) with the FEM values but with an overestimation of ~12%. Data were averaged to different time resolutions; 1 h time averaged concentrations showed the best fit with the FEM results (r=0.87). Data analyses suggested the potential of interferences due to temperature, relative humidity, nitrogen oxides, and volatile organic compounds. Correction models using temperature, humidity, and nitrogen dioxide (NO) were tested to relate the monitor concentrations to the FEM values. Temperature and humidity were two readily available variables. The model (#3) that added NO did not provide a substantial improvement in the fit. Thus, the models with only temperature and humidity can be easily developed by any user. The best model explained 91% of the variance and showed statistically significant improvement of the goodness of fits as well as decreased influence of the interfering variables on the diurnal and weekly patterns. The correction models were also able to lower the effect of seasonal temperature changes, allowing the use of the monitors over long-term sampling campaigns. Thus, the Aeroqual ozone monitor can return "FEM-like" concentrations after appropriate corrections. Data provided by a network of monitors could provide intra-urban spatial variations in ozone concentrations and provide more accurate human exposure assessments by reducing exposure misclassification.
Differentiating between local and remote pollution over Taiwan
Kishcha P, Wang SH, Lin NH, da Silva A, Lin TH, Lin PH, Liu GR, Starobinets B and Alpert P
In this study, an approach has been developed for differentiating between local and remote pollution over Taiwan, based on homogeneity perspective (variations of the standard deviation) of both AERONET measurements and NASA MERRA aerosol reanalysis (version 2, MERRA-2) over a 15-year period (2002 - 2017). The analysis of seasonal variations of the standard deviation of aerosol optical depth (AOD) measurements at six AERONET sites and MERRA AOD data in Taiwan showed that, in spring when remote aerosols dominate, the standard deviation is almost three times lower than that in autumn, when aerosols from local sources dominate. This finding was supported by MERRA AOD over the open ocean area: total AOD data were used to differentiate between local and remote pollution over both Taiwan and the open ocean area in the vicinity of Taiwan. Over Taiwan, MERRA total AOD showed a primary maximum in spring and a secondary one in autumn. Over the open ocean area, where there are no local sources of anthropogenic aerosols, MERRA total AOD showed only one maximum in spring and no maximum in autumn. This suggests that, in Taiwan, the maximum in autumn is attributed to local air pollution, while the pronounced maximum in spring is mainly caused by air pollution from continental Asia. The analyses of spatial distribution of 15-year monthly mean MERRA winds confirmed the above-mentioned results. Furthermore, similar to total AOD, MERRA sulfate AOD peaked in autumn over Taiwan, but not over the oceanic area: this indicates the contribution of local emissions of anthropogenic aerosols from the industrial sector. The standard deviation of MERRA sulfate AOD in spring is two-three times lower than the standard deviation in autumn: this is additional evidence that, in spring, sulfate aerosols from remote sources are predominant; while in autumn sulfate aerosols from local sources dominate.
Indoor Particle Alpha Radioactivity Origins in Occupied Homes
Kang CM, Liu M, Garshick E and Koutrakis P
Exposure to radioactivity inside homes potentially poses severe health risks which can be exacerbated by the interaction between radioactive particles and fine indoor particles; in particular, the presence of α particles are a key risk factor. Hence, in this study, particle radioactivity was concurrently measured in the family rooms and basements of 26 homes to assess its concentrations and identify its sources, both indoors and outdoors, across two seasons. The levels of radon, air ions, and particle radioactivity, which included short- and long-lived α-activity (SLA and LLA, respectively), varied greatly but were substantially higher in the basements. Also, particle radioactivity-as well as PM and sulfur concentrations-were lower during the heating season. SLA was associated with radon, which was consistently of indoor origin, whereas LLA was more strongly related to the sulfur measured in indoor PM, which is a proxy of outdoor infiltration. A regression model adjusted for sulfur and SLA also indicated a predominance of outdoor sources, likely due to the short residence time of indoor particles. Our results suggest that radiation in homes originates from both the decay of indoor radon and the infiltration of outdoor radioactivity.
Field Test of Several Low-Cost Particulate Matter Sensors in High and Low Concentration Urban Environments
Johnson KK, Bergin MH, Russell AG and Hagler GSW
Detailed quantification of the spatial and temporal variability of ambient fine particulate matter (PM) has, to date, been limited due to the cost and logistics involved with traditional monitoring approaches. New miniaturized particle sensors are a potential strategy to gather more time- and spatially-resolved data, to address data gaps in regions with limited monitoring and to address important air quality research priorities in a more cost-effective manner. This work presents field evaluations and lab testing of three models of low-cost (< $200) PM sensors (SHINYEI: models PPD42NS, PPD20V, PPD60PV) in three locations: urban background (average PM: 8 μg m) and roadside in Atlanta, Georgia, USA (average PM: 21 μg m), and a location with higher ambient concentrations in Hyderabad, India (average PM: 72 μg m). Sensor measurements were compared against reference monitors in the lab using one-minute averages and in field locations using one-hour averages. At the Atlanta sites the sensors were weakly correlated with a tapered element oscillating microbalance (TEOM) at best (R ≤ 0.30). In Hyderabad, the PPD20V sensors had the highest correlation with the environmental beta attenuation monitor (E-BAM) (R > 0.80), however the same sensors had poor agreement if the comparison was restricted to lower concentrations (R = ~0, < 40 μg m). The results of this work indicate the potential usefulness of these sensors, including the PPD20V, for higher concentration applications (< ~250 μg m). These field- testing results provide important insights into the varying performance of low-cost PM sensors under highly contrasting atmospheric conditions. The inconsistent performance results underscore the need for rigorous evaluation of optical particle sensors in the laboratory and in diverse field environments.
Three Years of High Time-resolution Air Pollution Monitoring in the Complex Multi-source Harbor of New York and New Jersey
Hagler G, Birkett D, Henry RC and Peltier RE
In densely developed port areas with numerous emissions sources, relating measured air quality changes to emissions is challenging given the geographic density of sources without unique pollutant composition signatures. To better understand air quality during increasing emission controls at the Port of New York and New Jersey ("Port"), an air monitoring station was sited to minimize collinearity of sources along ordinal directions. The study area includes an international airport, interstate highway, port terminals and shipping lanes, and industrial sources, as well as typical urban emissions of a megacity. Because air flow travel time from sources to the monitor were usually much less than one hour, minute-by-minute, high-precision data were collected for three years (2013-2015) for sulfur dioxide (SO), carbon monoxide (CO), oxides of nitrogen (NO, NO), black carbon (BC), fine particulate matter (PM), and meteorology (wind speed, wind direction, temperature, humidity). From summer 2014 to spring 2015, hourly metals data were also collected. A high degree of temporal variability was observed for pollutants associated with direct emissions, with highest hourly average coefficient of variation observed for NO (2.65), SO (1.45) and BC (1.21). Nonparametric trajectory analysis (NTA) was utilized to separate the source areas influencing the monitoring data and observe how they changed over time, with over 1.6 million trajectories computed in total. Comparing the last 5 quarters of the study to the first 5 quarters, concentrations at the monitoring site associated with three port-related geographic areas decreased by 34-41%, 11-17%, and 28-41% for SO, NO, and BC, respectively. Over the same period, indicators of shipping and cargo activity at the port remained relatively constant; therefore, a shift in emission factors is likely the cause of the change. This study demonstrates the value of high-time resolution, accurate monitoring data along with careful siting to understand source area influences.