IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS

Effects of Light Spectrum on Luminance Measurements in Underground Coal Mines
Martell MJ, , Sammarco JJ, Macdonald BD and
Lighting regulations for luminance in U. S. coal mines are verified in the field by using a luminance photometer calibrated to the Standard Illuminant A light source. Significant measurement errors can exist when measuring light sources that are dissimilar to light sources used to calibrate the photometer. This paper quantifies the measurement errors when measuring these dissimilar light sources commonly used in U.S. underground coal mines-an LED, a CFL with a clear cover, a CFL with an amber cover, and a tungsten halogen. The impact of photometer quality was also evaluated. Three different luminance measuring instruments of high, medium, and low quality were compared-a PR-650, LS-100, and PMEX, respectively. The PMEX was under evaluation for measuring luminance compliance in U.S. underground coal mines. The PR-650 was used as the referent to which the other photometers were compared. The PMEX error ranged from -17.0% to -26.5% with the highest error for the amber CFL. The LS-100 closely matched the luminance measurement for the LED and halogen; however, it had a percent error of -10.4% for the amber CFL. After the initial experiment, MSHA made improvements to the PMEX resulting in the PMEX-MSHA. The experiment was replicated using the new photometer and the newer PR-670. After repeating the experiment, the measurement errors ranged from -16% to -19% for the PMEX-MSHA, thus indicating an improvement over the PMEX. These results show that the spectral content of a light source and the photometer quality can greatly impact the accuracy of luminance measurement.
Intrinsically Safe Systems: Equivalency of International Standards Compared to U.S. Mining Approval Criteria
Calder W, Snyder DP and Burr JF
This paper provides a suitability determination of international standards for evaluating electrical and electronic systems and line powered apparatus as an alternative to the Mine Safety and Health Administration (MSHA) criteria for two-fault intrinsic safety approval. The primary issue is to demonstrate that international equipment evaluation standards will provide at least the same level of protection for miners as the MSHA requirements. The secondary issue is to identify additional benefits that may be derived from the use of the "entity concept" in the approval process, such as potential cost savings, and an easier and quicker path for the introduction of new technology.
Simulation and Measurement of Medium-Frequency Signals Coupling From a Line to a Loop Antenna
Damiano NW, Li J, Zhou C, Brocker DE, Qin Y, Werner DH and Werner PL
The underground-mining environment can affect radio-signal propagation in various ways. Understanding these effects is especially critical in evaluating communications systems used during normal mining operations and during mine emergencies. One of these types of communications systems relies on medium-frequency (MF) radio frequencies. This paper presents the simulation and measurement results of recent National Institute for Occupational Safety and Health (NIOSH) research aimed at investigating MF coupling between a transmission line (TL) and a loop antenna in an underground coal mine. Two different types of measurements were completed: 1) line-current distribution and 2) line-to-antenna coupling. Measurements were taken underground in an experimental coal mine and on a specially designed surface test area. The results of these tests are characterized by current along a TL and voltage induced in the loop from a line. This paper concludes with a discussion of issues for MF TLs. These include electromagnetic fields at the ends of the TL, connection of the ends of the TL, the effect of other conductors underground, and the proximity of coal or earth. These results could help operators by providing examples of these challenges that may be experienced underground and a method by which to measure voltage induced by a line.
Injury Surveillance and Safety Considerations for Large-Format Lead-Acid Batteries Used in Mining Applications
Reyes MA and Novak T
Large lead-acid batteries are predominantly used throughout the mining industry to power haulage, utility, and personnel-carrier vehicles. Without proper operation and maintenance, the use of these batteries can introduce mechanical and electrical hazards, particularly in the confined, and potentially dangerous, environment of an underground coal mine. A review of the Mine Safety and Health Administration accident/illness/injury database reveals that a significant number of injuries occur during the maintenance and repair of lead-acid batteries. These injuries include burns from electrical arcing and acid exposure, as well as strained muscles and crushed hands. The National Institute for Occupational Safety and Health investigated the design and implementation of these batteries to identify safety interventions that can mitigate these inherent hazards. This paper promotes practical design modifications, such as reducing the size and weight of battery assembly lids in conjunction with lift assists, as well as using five-pole cable connectors to improve safety.
Are Lithium Ion Cells Intrinsically Safe?
Dubaniewicz TH and DuCarme JP
National Institute for Occupational Safety and Health researchers are studying the potential for Li-ion-battery thermal runaway from an internal short circuit in equipment approved as permissible for use in underground coal mines. Researchers used a plastic wedge to induce internal short circuits for thermal runaway susceptibility evaluation purposes, which proved to be a more severe test than the flat plate method for selected Li-ion cells. Researchers conducted cell crush tests within a 20-L chamber filled with 6.5% CH-air to simulate the mining hazard. Results indicate that LG Chem ICR18650S2 LiCoO cells pose a CH explosion hazard from a cell internal short circuit. Under specified test conditions, A123 Systems 26650 LiFePO cells were safer than the LG Chem ICR18650S2 LiCoO cells at a conservative statistical significance level.
Dielectrophoretic Separation of Cancer Cells from Blood
Gascoyne PR, Wang XB, Huang Y and Becker FF
Recent measurements have demonstrated that the dielectric properties of cells depend on their type and physiological status. For example, MDA-231 human breast cancer cells were found to have a mean plasma membrane specific capacitance of 26 mF/m(2), more than double the value (11 mF/m(2)) observed for resting T-lymphocytes. When an inhomogeneous ac electric field is applied to a particle, a dielectrophoretic (DEP) force arises that depends on the particle dielectric properties. Therefore, cells having different dielectric characteristics will experience differential DEP forces when subjected to such a field. In this article, we demonstrate the use of differential DEP forces for the separation of several different cancerous cell types from blood in a dielectric affinity column. These separations were accomplished using thin, flat chambers having microelectrode arrays on the bottom wall. DEP forces generated by the application of ac fields to the electrodes were used to influence the rate of elution of cells from the chamber by hydrodynamic forces within a parabolic fluid flow profile. Electrorotation measurements were first made on the various cell types found within cell mixtures to be separated, and theoretical modeling was used to derive the cell dielectric parameters. Optimum separation conditions were then predicted from the frequency and suspension conductivity dependencies of cell DEP responses defined by these parameters. Cell separations were then undertaken for various ratios of cancerous to normal cells at different concentrations. Eluted cells were characterized in terms of separation efficiency, cell viability, and separation speed. For example, 100% efficiency was achieved for purging MDA-231 cells from blood at the tumor to normal cell ratio 1:1 x 10(5) or 1:3 x 10(5), cell viability was not compromised, and separation rates were at least 10(3) cells/s. Theoretical and experimental criteria for the design and operation of such separators are presented.
Simulation and Measurement of Through-the-Earth, Extremely Low-Frequency Signals Using Copper-Clad Steel Ground Rods
Damiano NW, Yan L, Whisner B and Zhou C
The underground mining environment can greatly affect radio signal propagation. Understanding how the earth affects signal propagation is a key to evaluating communications systems used during a mine emergency. One type of communication system is through-the-earth, which can utilize extremely low frequencies (ELF). This paper presents the simulation and measurement results of recent National Institute for Occupational Safety and Health (NIOSH) research aimed at investigating current injection at ELF, and in particular, ground contact impedance. Measurements were taken at an outside surface testing location. The results obtained from modeling and measurement are characterized by electrode impedance, and the voltage received between two distant electrodes. This paper concludes with a discussion of design considerations found to affect low-frequency communication systems utilizing ground rods to inject a current into the earth.
Peukert's Law for Supercapacitors with Constant Power Loads: Applicability and Application
Yang H
This paper examines the applicability of Peukert's law to supercapacitors with constant power loads and the application of this relationship in predicting the supercapacitor discharge time during a constant power discharge process. Originally developed for lead-acid batteries, Peukert's law states that the delivered charge increases when the discharge current decreases. This paper shows that Peukert's law applies to supercapacitors when the discharge power is above a certain threshold and does not apply anymore when the discharge power is sufficiently low. This pattern is due to the combined effects of three aspects of the supercapacitor physics: porous electrode structure, charge redistribution, and self-discharge. Based on the applicability study, this paper demonstrates the effectiveness of Peukert's law in predicting the supercapacitor discharge time during a constant power discharge process by conducting extensive experiments using three supercapacitor samples with different rated capacitances from different manufacturers at various voltages.
Design and implementation of a novel interior permanent magnet bearingless slice motor
Weinreb BS, Noh M, Fyler DC and Trumper DL
In this paper, we present a bearingless motor with a novel segmented dipole interior permanent magnet (IPM) slice rotor. The segmented dipole IPM rotor contains a unique pattern of interior permanent magnets arranged to generate a dipole air gap flux pattern. The magnets are encapsulated within an electrical steel rotor structure. The stator contains a three-phase, four-pole winding for suspension and a three-phase, two-pole winding for rotation. We present analyses of several candidate rotor designs. The analyses indicate that the segmented dipole IPM rotor achieves a reduced trade-off between force and torque capacity and relatively symmetric force dynamics as compared to prior art designs and alternate topologies. Symmetric and decoupled force dynamics allow a simple force decoupling algorithm to be used. We designed, constructed, and tested a prototype system. We experimentally demonstrate that the prototype system can achieve stable levitation and open-loop rotation.