A Single Microfluidic Device Approach to Direct Isolation, Purification, and Amplification of cfDNA from Undiluted Plasma
Circulating cell free DNA (cfDNA) is a valuable source of biomarkers for a range of medical applications including detection and monitoring of diseases. Currently, cfDNA sequence analysis must take place in a laboratory setting, due to the multiple steps required for processing including collection, purification, amplification, and analysis. Developing a point-of-care test system that combines these steps would simplify DNA processing thereby increasing diagnostic screening accessibility and enabling real-time monitoring for individual patients. Here, we have developed a system that combines multiple cfDNA processing steps into a single microfluidic-based device. This includes cfDNA collection directly from undiluted human plasma followed by purification and on chip amplification. A microelectrode array embedded within the microfluidic chip collected cfDNA through the creation of dielectrophoretic (DEP) forces. DEP utilizes differences in dielectric properties between cfDNA and plasma to preferentially induce a force on cfDNA. We then achieved on-chip amplification of collected DNA by designing a thermal cycling system to enable polymerase chain reaction (PCR) on the chip. This successfully consolidated the most labor-intensive steps of collection, purification, and amplification into a single device. Compared to elution of cfDNA for off-chip amplification, our on-chip PCR method improved the lower limit of detection by 3-fold and improved the total DNA yield by 5-fold. Furthermore, we demonstrate its clinical diagnostic potential by detecting mutations from a pancreatic ductal adenocarcinoma patient using only 60 μL of plasma. This paves the way for future development of a fully self-contained system facilitating the rapid detection of mutations in cfDNA.
Saliva-STAT: Sample-to-answer saliva test for COVID-19
Highly accessible and highly accurate diagnostics are necessary to combat rapidly-spreading infectious diseases, such as the recent COVID-19 pandemic. While lateral flow antigen tests have become pervasive, they are insufficiently sensitive to detect early or asymptomatic disease. Nucleic acid amplification tests provide the needed sensitivity, but accessibility of these tests continues to be a challenge due to the need for precise sample processing steps. Here we report a sample-to-answer test for saliva samples (saliva-STAT) that utilizes a battery-powered handheld instrument and a low-cost easily-manufacturable sample cassette to perform a nucleic acid amplification test for viral pathogens. To enable a completely automated assay, we leverage thermally responsive alkane partitions (TRAPs) and paramagnetic beads for virus purification and concentration, as well as reagent addition and mixing. Notably, the saliva STAT easily accommodates directly-dispensed saliva samples (in contrast to microfluidic devices), which is necessary for self-testing. Using the saliva-STAT platform, we demonstrate detection of down to 0.2 copies/μL of SARS-CoV-2 virus in saliva samples. We envision that the saliva-STAT could be used in walk-in clinics, mobile clinics, public testing locations, and in the home. With minor adjustments to the assay, the saliva-STAT platform can easily be adapted for other respiratory viruses, such as Influenza.
An Acoustofluidic Picoinjector
Droplet microfluidics has emerged as a valuable technology for a multitude of chemical and biomedical applications, offering the capability to create independent microenvironments for high-throughput assays. Central to numerous droplet microfluidic applications is the picoinjection of materials into individual droplets, yet existing picoinjection methods often exhibit high power requirements, lack biocompatibility, and/or suffer from limited controllability. Here, we present an acoustofluidic picoinjector that generates acoustic pressure at the droplet interface to enable on-demand, energy-efficient, and biocompatible injection at high precision. We validate our platform by performing acid-base titrations by iteratively injecting picoliter volume reagents into droplets to induce pH transitions detectable by color change in solution. Additionally, we demonstrate the versatility of the acoustofluidic picoinjector in the synthesis of metallic nanoparticles, yielding highly monodisperse and reproducible particle morphologies compared to conventional bulk-phase techniques. By facilitating controlled delivery of reagents or biological samples with unparalleled accuracy, acoustofluidic picoinjection broadens the utility of droplet microfluidics for a myriad of applications in chemical and biological research.
Suppression of Resistive Coupling in Nanogap Electrochemical Cell: Resolution of Dual Pathways for Dopamine Oxidation
A nanogap cell involves two working electrodes separated by a nanometer-wide solution to enable unprecedented electrochemical measurements. The powerful nanogap measurements, however, can be seriously interfered with by resistive coupling between the two electrodes to yield erroneous current responses. Herein, we employ the nanogap cell based on double carbon-fiber microelectrodes to suppress resistive coupling for the assessment of intrinsic current responses. Specifically, we modify a commercial bipotentiostat to compensate the Ohmic potential drop shared by the two electrodes through the common current pathway with a fixed resistance in the solution. Resistive coupling through both non-Faradaic and Faradaic processes is suppressed to eliminate erroneous current responses. Our approach is applied to investigate the mechanism of dopamine oxidation at carbon-fiber microelectrodes as important electrochemical sensors for the crucial neurotransmitter. Resistive coupling is suppressed to manifest the intrinsic current responses based on the oxidation of both adsorbed and non-adsorbed forms of dopamine to the respective forms of dopamine--quinone. The simultaneous dual oxidation pathways are observed for the first time and can be mediated through either non-concerted or concerted mechanisms of adsorption-coupled electron transfer. The two mechanisms are not discriminated for the two-electron oxidation of dopamine because it can not be determined whether the intermediate, dopamine semi-quinone, is adsorbed on the electrode surface. Significantly, our approach will be useful to manifest intrinsic current responses without resistive coupling for nanogaps and microgaps, which are too narrow to eliminate the common solution resistance by optimizing the position of a reference electrode.
Sterilization Effects on Nitric Oxide-Releasing Glucose Sensors
Nitric oxide (NO) release from -nitrosothiol-modified mesoporous silica nanoparticles imbedded in the diffusion limiting layer of a glucose sensor has been demonstrated as an effective strategy for mitigating the foreign body response common to sensor implantation, resulting in improved analytical performance. With respect to potential clinical translation of this approach, the effects of sterilization on NO-releasing biosensors require careful evaluation, as NO donor chemistry is sensitive to temperature and environment. Herein, we evaluated the influence of multiple sterilization methods on 1) sterilization success; 2) NO payload; and 3) sensor performance to establish the commercialization potential of NO-releasing glucose sensors. Sensors were treated with ethylene oxide gas, the most common sterilization method for intricate medical devices, which led to undesirable (i.e., premature) release of NO. To reduce NO loss, alternative sterilization methods that were studied included exposure to ultraviolet (UV) light and immersion in 70% ethanol (EtOH). Sterilization cycle times required to reach a 10 sterility assurance level were determined for both UV light and 70% EtOH against Gram-negative and -positive bacteria. The longest sterilization cycle times (258 s and 628 s for 70% EtOH and UV light, respectively) resulted in a negligible impact on benchtop sensor performance. However, sterilization with 70% ethanol resulted in a reduced NO-release duration. Ultraviolet light exposure for ~10 min proved successful at eliminating bacteria without compromising NO payloads or durations and presents as the most promising method for sterilization of these sensors. In addition, storage of NO-releasing sensor membranes at -20 and -80°C resulted in preservation of NO release for 6 and 12 months, respectively.
Engineering vascularized skin-mimetic phantom for non-invasive Raman spectroscopy
Recent advances in Raman spectroscopy have shown great potential for non-invasive analyte sensing, but the lack of a standardized optical phantom for these measurements has hindered further progress. While many research groups have developed optical phantoms that mimic bulk optical absorption and scattering, these materials typically have strong Raman scattering, making it difficult to distinguish metabolite signals. As a result, solid tissue phantoms for spectroscopy have been limited to highly scattering tissues such as bones and calcifications, and metabolite sensing has been primarily performed using liquid tissue phantoms. To address this issue, we have developed a layered skin-mimetic phantom that can support metabolite sensing through Raman spectroscopy. Our approach incorporates millifluidic vasculature that mimics blood vessels to allow for diffusion akin to metabolite diffusion in the skin. Furthermore, our skin phantoms are mechanically mimetic, providing an ideal model for development of minimally invasive optical techniques. By providing a standardized platform for measuring metabolites, our approach has the potential to facilitate critical developments in spectroscopic techniques and improve our understanding of metabolite dynamics .
Near-infrared Absorption and Emission Probes with Optimal Connection Bridges for Live Monitoring of NAD(P)H Dynamics in Living Systems
Two NAD(P)H-biosensing probes consisting of 1,3,3-trimethyl-3H-indolium and 3-quinolinium acceptors, linked by thiophene, , and 3,4-ethylenedioxythiophene, , bridges are detailed. We synthesized probes and , replacing the thiophene connection in probe with phenyl and 2,1,3-benzothiadiazole units, respectively. Probe was prepared by substituting probe 's 3-quinolinium unit with a 1-methylquinoxalin-1-ium unit. Solutions are non-fluorescent but in the presence of NADH, exhibit near-infrared fluorescence at 742.1 nm and 727.2 nm for probes and , respectively, and generate absorbance signals at 690.6 nm and 685.9 nm. In contrast, probes and displayed pronounced interference from NADH fluorescence at 450 nm, whereas probe exhibited minimal fluorescence alterations in response to NAD(P)H. Pre-treatment of A549 cells with glucose in the presence of probe led to a significant increase in fluorescence intensity. Additionally, subjecting probe to lactate and pyruvate molecules resulted in opposite changes in NAD(P)H levels, with lactate causing a substantial increase in fluorescence intensity, conversely, pyruvate resulted in a sharp decrease. Treatment of A549 cells with varying concentrations of the drugs cisplatin, gemcitabine, and camptothecin (5, 10, and 20 μM) led to a concentration-dependent increase in intracellular fluorescence intensity, signifying a rise in NAD(P)H levels. Finally, fruit fly larvae were treated with different concentrations of NADH and cisplatin illustrating applicability to live organisms. The results demonstrated a direct correlation between fluorescence intensity and the concentration of NADH and cisplatin, respectively, further confirming the efficacy of probe in sensing changes in NAD(P)H levels within a whole organism.
Electrochemical Immunosensor for the Quantification of Galectin-3 in Saliva
Heart failure (HF) is an emerging epidemic and remains a major clinical and public health problem. Advances in the healthcare management of HF may lead to lower morbidity and mortality rates but require diagnostics to guide the process. Current diagnostics/prognostics approaches rely on expensive equipment, centralized facilities and trained personnel, marginalizing healthcare access in developing countries and rural communities. These issues have led researchers to focus on developing portable and affordable diagnostics that can be deployed at the point-of-care (POC). Typically, HF biomarkers are measured in blood not saliva. Recently, our team correlated concentrations of salivary Galectin-3 (Gal-3) to outcomes in patients with HF. We have developed an analytical device which consists of an immunoassay based on a screen-printed carbon electrode (SPCE) to quantify Gal-3 levels in saliva samples. Using 10 μL of saliva, the proposed electrochemical immunoassay achieved a concentration dependent signal response in the clinically relevant range with a limit of detection of 9.66 ng/mL. In addition, the storage stability of the modified electrode was investigated, and only a 10.9% loss in current response over a 35-day period. The results of the immunoassay on the modified SPCEs suggest validity as a POC biosensor system for the management of HF.
Assessing Aptamer-Analyte Binding Kinetics by Microfluidic Fluorescence Microscopy
Kinetic measurement plays a crucial role in understanding aptamer binding mechanisms and identifying appropriate aptamers for clinical and research applications. Current techniques, while well established, generally require large sample volumes, bulky and expensive instruments operated by trained personnel, and are hence not readily accessible to resource-limited research laboratories. This paper presents a fluorescence microscopy-based microfluidic assay for measuring aptamer-analyte binding kinetics in a simple and cost-effective manner. Kinetic measurements are achieved by monitoring time-course fluorescence of fluorescently labeled aptamers as they bind to the targets trapped in a microfluidic chip. Fluorescence measurements are performed on a standard fluorescence microscope and are accessible to laboratories with only modest resources. Moreover, microfluidic technology allows efficient and cost-effective immobilization of small amounts of target molecules or live cells as well as flow-based manipulation of aptamers for the measurements. Kinetic measurements of aptamer binding to immunoglobulin E protein and CCRF-CEM cells have yielded results consistent with those obtained from established methods, demonstrating the potential utility of our method for exploring aptamer-target interactions and identifying aptamers that best suit specific given biomedical applications.
Self-powered freestanding multifunctional microneedle-based extended gate device for personalized health monitoring
Online monitoring of prognostic biomarkers is critically important when diagnosing disorders and assessing individuals' health, especially for chronic and infectious diseases. Despite this, current diagnosis techniques are time-consuming, labor-intensive, and performed offline. In this context, developing wearable devices for continuous measurements of multiple biomarkers from body fluids has considerable advantages including availability, rapidity, convenience, and minimal invasiveness over the conventional painful and time-consuming tools. However, there is still a significant challenge in powering these devices over an extended period, especially for applications that require continuous and long-term health monitoring. Herein, a new freestanding, wearable, multifunctional microneedle-based extended gate field effect transistor biosensor is fabricated for online detection of multiple biomarkers from the interstitial fluid including sodium, calcium, potassium, and pH along with excellent electrical response, reversibility, and precision. In addition, a hybrid powering system of triboelectric nanogenerator and solar cell was developed for creating a freestanding, closed-loop platform for continuous charging of the device's battery and integrated with an Internet of Things technology to broadcast the measurements online, suggesting a stand-alone, stable multifunctional tool which paves the way for advanced practical personalized health monitoring and diagnosis.
Role of Electrode Configuration and Morphology in Printed Prothrombin Time Sensors
Patients on long-term anticoagulation therapy require frequent testing of prothrombin time/international normalized ratio (PT/INR) to ensure therapeutic efficacy. Point-of-care (POC) PT tests for at-home monitoring eliminate the burden of visiting the clinic, but realizing a cost-effective and robust at-home POC test for PT has remained elusive. Recent demonstrations of printed PT sensors show promise for addressing the cost concerns; however, the printed sensors have lacked quality control to ensure reliability between tests. In this work, on-chip redundancy is introduced with fully printed impedimetric PT sensors by incorporating simultaneous testing with a single fingerstick volume of blood (8 μL). The influence of electrode dimensions and composition were studied, revealing an optimal electrode spacing of 200 μm and an unexpected dependence on the morphology of the electrodes. Three distinct silver morphologies were studied: aerosol jet printed silver nanoparticles (AgNPs), aerosol jet printed silver nanowires (AgNWs), and evaporated silver (Ag). In general, AgNPs exhibited the best PT sensor performance, due to relatively low conductance and high porosity. Overall, the printed impedimetric PT sensor functionalization was improved by incorporating simultaneous testing and, when combined with a handheld control device, shows promise for leading to a system that overcomes the challenges of commercial PT/INR coagulometers.
PATHPOD - A loop-mediated isothermal amplification (LAMP)-based point-of-care system for rapid clinical detection of SARS-CoV-2 in hospitals in Denmark
Sensitive and rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been a vital goal in the ongoing COVID-19 pandemic. We present in this comprehensive work, for the first time, detailed fabrication and clinical validation of a point of care (PoC) device for rapid, onsite detection of SARS-CoV-2 using a real-time reverse-transcription loop-mediated isothermal amplification (RT-LAMP) reaction on a polymer cartridge. The PoC system, namely PATHPOD, consisting of a standalone device (weight less than 1.2 kg) and a cartridge, can perform the detection of 10 different samples and two controls in less than 50 min, which is much more rapid than the golden standard real-time reverse-transcription Polymerase Chain Reaction (RT-PCR), typically taking 16-48 h. The novel total internal reflection (TIR) scheme and the reactions inside the cartridge in the PoC device allow monitoring of the diagnostic results in real-time and onsite. The analytical sensitivity and specificity of the PoC test are comparable with the current RT-PCR, with a limit of detection (LOD) down to 30-50 viral genome copies. The robustness of the PATHPOD PoC system has been confirmed by analyzing 398 clinical samples initially examined in two hospitals in Denmark. The clinical sensitivity and specificity of these tests are discussed.
Dual-clamped one-pot SERS-based biosensors for rapid and sensitive detection of SARS-CoV-2 using portable Raman spectrometer
Rapid and sensitive diagnostics of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is of utmost importance to control the widespread coronavirus disease 2019 (COVID-19) upsurge. This study demonstrated a novel one-pot surface-enhanced Raman scattering (SERS) based immunoassay to detect SARS-CoV-2, without any washing process using a portable Raman spectrometer. The SERS-immune assay was designed using a regular digital versatile disk (DVD) substrate integrated with Raman reporter labeled silver nanoparticles for double clamping effects. The disks were molded to form nanopillar arrays and coated with silver film to enhance the sensitivity of immunoassay. The SERS platform demonstrated a limit of detection (LoD) up to 50 pg mL for SARS-CoV-2 spike protein and virus-like-particle (VLP) protein in phosphate buffer saline within a turnaround time of 20 mins. Moreover, VLP protein spiked in untreated saliva achieved an LoD of 400 pg mL, providing a cycle threshold (Ct) value range of 30-32, closer to reverse transcription-polymerase chain reaction (RT-PCR) results (35-40) and higher than the commercial rapid antigen tests, ranging from 25 to 28. Therefore, the developed one-pot SERS based biosensor exhibited highly sensitive and rapid detection of SARS-CoV-2, which could be a potential point-of-care platform for early and cost-effective diagnosis of the COVID-19 virus.
MASTR Pouch: Palm-size lab for point-of-care detection of Mpox using recombinase polymerase amplification and CRISPR technology
Mpox (formerly referred as Monkeypox) outbreak has been declared a Public Health Emergency of International Concern. However, traditional polymerase chain reaction (PCR) diagnostic technology is not ideal for on-site applications. To conduct the sample-to-result Mpox viral particles detection outside the laboratories, we developed an easy-to-operate palm-size pouch, termed Mpox At-home Self-Test and point-of-caRe Pouch (MASTR Pouch). In this MASTR Pouch, the fast and accurate visualization was achieved by incorporating recombinase polymerase amplification (RPA) with clustered regularly interspaced short palindromic repeat (CRISPR)/Cas12a system. From viral particle lysis to naked eye readout, MASTR Pouch required only four simple steps to accomplish the analysis process within 35 min. Fifty-three Mpox pseudo-viral particles in exudate (10.6 particles/μL) were able to be detected. To verify the practicability, 104 mock Mpox clinical exudate specimens were tested. The clinical sensitivities were determined to be 91.7%- 95.8%. There was no false-positive result, validating the 100% clinical specificity. MASTR Pouch approaches the WHO's ASSURD criteria for point-of-care diagnostic, which will be beneficial for mitigating Mpox's global spread. The versatility potential of MASTR Pouch could further revolutionize infection diagnosis.
One-step-one-pot hydrothermally derived metal-organic-framework-nanohybrids for integrated point-of-care diagnostics of SARS-CoV-2 viral antigen/pseudovirus utilizing electrochemical biosensor chip
The COVID-19 pandemic has become a global catastrophe, affecting the health and economy of the human community. It is required to mitigate the impact of pandemics by developing rapid molecular diagnostics for SARS-CoV-2 virus detection. In this context, developing a rapid point-of-care (POC) diagnostic test is a holistic approach to the prevention of COVID-19. In this context, this study aims at presenting a real-time, biosensor chip for improved molecular diagnostics including recombinant SARS-CoV-2 spike glycoprotein and SARS-CoV-2 pseudovirus detection based on one-step-one-pot hydrothermally derived CoFeBDCNH-CoFeO MOF-nanohybrids. This study was tested on a PalmSens-EmStat Go POC device, showing a limit of detection (LOD) for recombinant SARS-CoV-2 spike glycoprotein of 6.68 fg/mL and 6.20 fg/mL in buffer and 10% serum-containing media, respectively. To validate virus detection in the POC platform, an electrochemical instrument (CHI6116E) was used to perform dose dependent studies under similar experimental conditions to the handheld device. The results obtained from these studies were comparable indicating the capability and high detection electrochemical performance of MOF nanocomposite derived from one-step-one-pot hydrothermal synthesis for SARS-CoV-2 detection for the first time. Further, the performance of the sensor was tested in the presence of Omicron BA.2 and wild-type D614G pseudoviruses.
CRISPR-powered Biosensing Platform for Quantitative Detection of Alpha-fetoprotein by a Personal Glucose Meter
Alpha-fetoprotein (AFP) is an important protein biomarker of liver cancer, as its serum levels are highly correlated with the progression of disease. Conventional immunoassays for AFP detection rely on enzyme-linked immunosorbent assay analyses with expensive and bulky equipment. Here, we developed a simple, affordable, and portable CRISPR-powered personal glucose meter biosensing platform for quantitative detection of the AFP biomarker in serum samples. The biosensor takes advantage of the excellent affinity of aptamer to AFP and the collateral cleavage activity of CRISPR-Cas12a, enabling sensitive and specific CRISPR-powered protein biomarker detection. To enable point-of-care testing, we coupled invertase-catalyzed glucose production with the glucose biosensing technology to quantify AFP. Using the developed biosensing platform, we quantitatively detected AFP biomarker in spiked human serum samples with a detection sensitivity of down to 10 ng/mL. Further, we successfully applied the biosensor to detect AFP in clinical serum samples from patients with liver cancer, achieving comparable performance to the conventional assay. Therefore, this novel CRISPR-powered personal glucose meter biosensor provides a simple yet powerful alternative for detecting AFP and potentially other tumor biomarkers at the point of care.
Label-free detection of synthetic, full genomic length HIV-1 RNA at the few-copy level
Oligonucleotide-functionalized graphene biosensors show immense promise for use as label-free point of care devices for detection of nucleic acid biomarkers at clinically relevant levels. Graphene-based nucleic acid sensors can be fabricated at low cost and have been shown to reach limits of detection in the attomolar range. Here we demonstrate devices functionalized with 22mer or 8omer DNA probes are capable of detecting full length genomic HIV-1 subtype B RNA, with a limit of detection below 1 aM in nuclease free water. We also show that these sensors are suitable for detection directly in Qiazol lysis reagent, again with a limit of detection below 1 aM for both 22mer and 8omer probes.
Self-enhancement lateral flow immunoassay for COVID-19 diagnosis
Equipment-free colorimetric-based lateral flow immunoassay (LFIA) is the most convenient and popular tool for various applications, including diagnostic tools requiring high sensitivity for the detection of pathogens. Thus, improvements and developments of LFIA are constantly being reported. Herein, we enriched the sensitivity of LFIA using the gold enhancement principle, emphasizing needlessly complicated apparatus, only one step for the strip test operation, and typical time incubation (15 min) process. Self-enhanced LFIA was then executed for subsequent flows by overlapping the additionally enhanced pad composed of gold ions and reducing agent on the conjugate pad and the sample pad. Self-enhanced LFIA was performed to detect SARS-CoV-2 antigens in saliva. The obtained result depicted that the achieved sensitivity was up to tenfold compared with that of conventional LFIA by visual measurements. The detection limits of self-enhanced LFIA detecting nucleocapsid protein antigens in the saliva sample was 0.50 and 0.10 ng/mL employed by naked eye detection and calibration curve-based calculation, respectively. When the proposed device was applied to 207 human saliva samples, the diagnostic performance presented a 96.10 % sensitivity and 99.23 % specificity. This self-enhanced LFIA could be implemented in large-scale production and demonstrates higher sensitivity with effortless use, which meets the requirements for point-of-care testing and on-field mass screening.
Longitudinal analysis of anti-SARS-CoV-2 neutralizing antibody (NAb) titers in vaccinees using a novel giant magnetoresistive (GMR) assay
The COVID-19 pandemic has highlighted the need to monitor important correlates of immunity on a population-wide level. To this end, we have developed a competitive assay to assess neutralizing antibody (NAb) titer on the giant magnetoresistive (GMR) biosensor platform. We compared the clinical performance of our biosensor with established techniques such as Ortho's VITROS Anti-SARS-CoV-2 IgG Quantitative Antibody test. Results obtained between the VITROS test and the GMR assay showed correlation ( = -0.93). We then validated the assay with patient plasma samples that had been tested using focus reduction neutralization testing (FRNT). The results obtained from our GMR assay exhibit a previously identified trend of increased NAb titers 2 weeks post-vaccination. We further evaluated NAb titers 6 months post-vaccination and observed waning neutralizing antibody titers over that time in vaccinated patients. In addition, we calibrated our assay to an arbitrary unit (IU/mL) using World Health Organization (WHO) reference plasma provided by the National Institute of Biological Standards and Control (NIBSC). Our biosensor provides highly specific and sensitive results in serum and plasma with analytical, clinical, and point-of-care (POC) applications due to quick turnaround times on samples and the cost-effectiveness of the platform.
Enhancement of faradaic current in an electrochemical cell integrated into silicon microfluidic channels
Implantable electrochemical sensors enable fast and sensitive detection of analytes in biological tissue, but are hampered by bio-foulant attack and are unable to be recalibrated in-situ. Herein, an electrochemical sensor integrated into ultra-low flow (nL/min) silicon microfluidic channels for protection from foulants and in-situ calibration is demonstrated. The small footprint (5 μm radius channel cross-section) of the device allows its integration into implantable sampling probes for monitoring chemical concentrations in biological tissues. The device is designed for fast scan cyclic voltammetry (FSCV) in the thin-layer regime when analyte depletion at the electrode is efficiently compensated by microfluidic flow. A 3X enhancement of faradaic peak currents is observed due to the increased flux of analytes towards the electrodes. Numerical analysis of in-channel analyte concentration confirmed near complete electrolysis in the thin-layer regime below 10 nL/min. The manufacturing approach is highly scalable and reproducible as it utilizes standard silicon microfabrication technologies.
Self-assembled porous polymer films for improved oxygen sensing
Absolute oxygen sensors based on quenching of phosphorescence have been the subject of numerous studies for the monitoring of biological environments. Here, we used simple fabrication techniques with readily available polymers to obtain high performance phosphorescent films. Specifically, evaporation-based phase separation and the breath figure technique were used to induce porosity. The pore sizes ranged from 37 nm to 141 m while the maximum average porosity achieved was 74%. The oxygen sensing properties were evaluated via a standarised calibration procedure with an optoelectronic setup in both transmission and reflection based configurations. When comparing non-porous and porous films, the highest improvements achieved were a factor of 7.9 in dynamic range and 7.3 in maximum sensitivity, followed by an improved linearity with a half-sensitivity point at 43% O V/V. Also, the recovery time was reduced by an order of magnitude in the high porosity film and all samples prepared were not affected by variations in the humidity of the surrounding environment. Despite the use of common polymers, the fabrication techniques employed led to the significant enhancement of oxygen sensing properties and elucidated the relation between porous film morphologies and sensing performance.